Nominal System Voltage 110kv Line Composite Polymeric ZnO Arresters

Nominal System Voltage 110kv Line Composite Polymeric ZnO Arresters

hv transmission line composite polymeric silicone zno arresters 0.28kV~500kV Surge Arresters' Characteristics: 1. The Co;
Basic Info.
Model NO. YH10CX-120
Installation Parallel Arrester
Application Substation
Size Meidum
Operation Voltage High Voltage
Shape Cuboid
Material ZnO
Certification ISO9001, Kema
Brand Yongde
Housing Material Silicone/Polymer/Composite Housing
OEM/ODM Accept
Accessory Bracket,Insulating Cap,Cooper Lead,Insulator,Hoop
Color Grey
Purpose Over-Voltage Protection
Warranty 2 Years
Transport Package by Wood Carton
Specification Iec60099-4
Trademark YONGDE
Origin China, Zhejiang
HS Code 85354000
Production Capacity 5000PCS/Year
Product Description
hv transmission line composite polymeric silicone zno arresters

0.28kV~500kV Surge Arresters' Characteristics:
1. The Core column applied winding structure, Polymer Housed core pillar molded on the core column, with almost no internal air gap, and outstanding sealing performance Simple in structure, small in size and light in weight.
2. Polymer Housed with silicone rubber, explosion-proof ZnO varistor as the core component is large
in flow capacity.
3. International standard IEC 60099-4 and ANSI 62.22, and with high reliability. With fully insulated tops, the product can be applied to the complete cabinet installation, which can reduce the designing size of cabinet.
4. Products with detachment device can provide signals for quitting operation when failure occurs,
avoiding arrester explosion, and it is maintenance-free.
5. Polymer housed products with a six CTI level, creepage distance meets the requirements of IV level in heavy pollution areas.

Technical Parameters:

Working condition:


Line discharge level from 1 to 5,


Type Nominal System Voltage Rated Voltage Minimum Reference Voltage under 1 mA DC Residual voltages at steep impulse current Residual voltages at lightning impulse 1.2/50 Impulse Discharge Voltage kV< =(+) Power Frequency Withstand Voltage 4/10 μ S High Current (KA) 2mS current /A
5kA 10kA 5kA 10kA
YH10CX-90/260 110 90 130 292 260 525 185 100 600
YH10CX-96/280 110 96 140 314 280 525 185 100 600
YH10CX-102/296 110 102 148 332 296 525 185 100 600
YH10CX-120/320 132 120 170 365 320 535 210 100 850
Environment temperature: -40--+40 degree
altitude:<1000m
48HZ<Rated frequency<62HZ
Power frequency voltage should not be more than continuous running voltage
Max wind speed should be less than 35m/s
Earthquake intensity should be less than 7 degree
If used in contamination area, should be noted in advance.